Lafayette Instrument Logo
Lafayette Instrument Logo

RELATED CATEGORIES
Biofeedback > Acquisition Modules

EDA, PULSE, TEMP, AND MOTILITY MODULE

Model 73200

EDA, Pulse, Temp, and Motility Module
 
   
 

DETAILS

Bluetooth Module for sensing Skin Conductance, Pulse Frequency, Temperature, and Motility.

SPECIFICATIONS

MODULE SPECIFICATIONS

  • Channels: 4
  • Notch Filter: 50/60Hz
  • Class 2 Bluetooth
  • Operating distance: ~10m
  • Transmission power: 10mW

BVP* SPECIFICATIONS

  • Sample rate: 500 Hz
  • Integration time constant: 100ms
  • Artifact detection: extrasystoles
  • Range: 0-100%
  • Gain: Automatic adjustment
  • Heart rate: 30-200 beats/minute

* PVA/PULS calculated from BVP

TEMPERATURE (DIGITAL SENSOR) SPECIFICATIONS

  • Date rate: 4 values per second
  • Range: 10-40°C
  • Accuracy: 0.5°C
  • Resolution: 0.01°C

SKIN CONDUCTANCE LEVEL (SCL) SPECIFICATIONS

  • Measuring with alternate current: 20 Hz alternated
  • Sample rate: 2kHhz
  • Range: 0-50 μS
  • Max. error: 0.65 μS
  • Resolution: 0.012 μS (12 nS)

MOTILITY (3 AXIS ACCELERATION) SPECIFICATIONS

  • Sample rate: 200 Hz
  • Range: 0-20 m/s²
  • Accuracy: 0.006 m/s²
  • Resolution: 0.05 m/s²

Used to record the client's movement, artifact recognition. Recorded with a 3-axis acceleration sensor integrated into the Multi module.

DATA STORAGE RATE**

  • vSCL: 10-40 data/second
  • BVP: 10-100 data/second
  • TEMP: 4 values/second
  • MOT: 2-10 data/second

** Adjustable via software

ACCESSORIES

REQUIRED ACCESSORIES

EDA Electrode Cable with Finger Plates Image

EDA Electrode Cable with Finger Plates
Model 73300

EDA cable sets, either reusable plates or with snap for disposable electrode.

Temperature Sensor Image

Temperature Sensor
Model 73305

Temperature sensor for Biofeedback module 73200.

Pulse Sensor Image

Pulse Sensor
Model 73306

Finger Pulse sensor for Biofeedback module 73200.

Multi Sensor Image

Multi Sensor
Model 73311

This is a 3-sensor which can be easily attached to a single finger. The Velcro strap sensor includes gold plates for electro-dermal activity (EDA) measurement, a built-in skin temperature sensor and an LED pair to measure the pulse plethysmograph.

CONTACT US

Lafayette Instrument Company
3700 Sagamore Pkwy N
Lafayette, IN 47904

Phone: (765) 423-1505
Fax: (765) 423-4111
info@lafayetteinstrument.com

 

Home | Products | Support | About | Sitemap | Privacy

Copyright © 2009 - 2017 Lafayette Instrument Company. All Rights Reserved.


Top

PRODUCT SEARCH

Use this form to search for products from the Lafayette Instrument Online Family.



CONTACT US

Lafayette Instrument Company
3700 Sagamore Pkwy N
Lafayette, IN 47904

Phone: (765) 423-1505
Fax: (765) 423-4111

info@lafayetteinstrument.com

Copyright © 2009 - 2017 Lafayette Instrument Company. All Rights Reserved.